Early access · taking pilot sites in Alberta

Proof every inspection happened.

QR tags on your fire extinguishers, first aid kits, eyewash stations, exit lights and the rest of your emergency equipment. Your own crew scans each routine check on their phone. The record shows who checked it, when, where, and what they saw. A missed check is flagged as missed. It is never counted as a pass.

EXT-07 · Bay 3, north wall
Fire extinguisher, monthly
Pass
Checked by
J. Example, lead hand
Server time
2026-10-14 07:42 MT
Location
On site · ±18 m
Photo
Gauge and tamper seal
Next due
2026-11-13
EYE-02 · weekly flush, due Oct 9Missed

Example record. Names and times are illustrative.

How it works

Your crew already does the checks. Now the checks leave a record.

Step 1

Tag

Put a NotifyMe tag on each item. Its schedule comes from the rule that governs it: monthly extinguishers, weekly eyewash flushes, scaffold tags every 21 days.

Step 2

Scan

The person doing the check signs in on their phone once (it stays signed in), scans the tag and taps through the checklist. A photo is optional, and recommended when something fails.

Step 3

Flag

A missed check or a failed item that hasn't been fixed raises an alert to the person you choose. A failure stays open until someone records the repair.

Step 4

Export

Hand your auditor a CSV export (opens in Excel), or send each result to the EHS software you already use.

What every record holds

A record an auditor can trust.

A paper tag can be initialled at the end of the month without anyone walking the floor. A NotifyMe record carries the evidence with it.

For your auditor

Built around what a COR audit looks for in inspections.

COR audits check that inspections happen as often as your program says, that problems get fixed on time, and that defective equipment stays out of use. The dashboard is laid out the same way.

What the auditor asksWhat you show them
Are inspections done as often as your program says?Schedule versus completed, by equipment type and area, for any period.
Which ones were missed?A list of every missed check with its due date. Missed checks are never blank and never shown as passed.
Were problems fixed on time?A list of every problem with its risk rank, when it was found, what was done, when it was closed and by whom.
Is defective equipment kept out of use?The items tagged out of service, and since when.
Who did the inspections?Every person who did checks, and each check saved under their name.

Mapped to the Energy Safety Canada 2023 COR audit protocol (Element D, Inspections) and the BC COR audit (Element 4, Inspections). Using NotifyMe Inspect does not by itself meet any audit requirement. Your program and your auditor decide that.

Equipment

The routine checks your own crew is allowed to do.

Each one has a default schedule taken from the rule that governs it. Where no law sets an interval, the schedule is yours to set, and the app says so. Certified work like annual extinguisher service and fire alarm testing stays with your contractors. We remind you when it's due and record that it happened.

Monthly · fire code

Fire extinguishers

In place, gauge in the green, pin and seal intact, tag current. Photo of the gauge and seal.

Monthly · fire code

Emergency lights and exit signs

Exit sign lit, charge light on, test button lights the lamps on battery.

Weekly · ANSI Z358.1

Eyewash stations and showers

Clear access, full flow, water runs clear, caps in place.

Monthly and after use

First aid kits

In place, sealed or stocked, nothing expired. Photo of the kit.

Monthly · fire code

Fire doors

Closes and latches on its own, never wedged open.

Monthly · fire code

Fire alarm panel and pull stations

Panel shows normal, pull stations clear. For staff trained on the panel.

Monthly · OHS

Emergency SCBA and respirators

Cylinder full and in test date, facepiece and alarm working.

Every 21 days · OHS

Scaffold tags

Tag current and the right colour, base, rails and planks complete. Photo of the tag.

Monthly

AEDs

Status light ready, pads and battery in date.

Monthly

Naloxone kits

In place, sealed, not expired.

Monthly

Spill kits

Sealed and fully stocked.

Monthly

Gas cylinder storage

Chained upright, caps on, oxygen kept apart from fuel gas.

Coming next: per-shift checks. Harnesses, forklifts and mobile equipment, cranes and hoists, slings, ladders and gas-detector bump tests, recorded by the operator each shift. Each item is added only after we've checked the rule that governs it.

What it is, and what it isn't

A reporting tool. Your program stays yours.

It records and alerts

It keeps proof that a check happened, flags the checks that didn't, and tells the right person when something failed and wasn't fixed.

It doesn't certify anything

The named person does the check and stays accountable for it. No computer judges the equipment: photos are only screened for offensive content before anyone sees them.

It works alongside your EHS software

Results can go to the EHS software you already run, by webhook or by file. You don't have to move your program onto ours.

Your records stay in Canada

Inspection records and photos are stored in Canada (Montreal). NotifyMe is an owner alert system, not an emergency service. In an emergency, call 911.

Run a pilot at your shop or site.

We're taking the first pilot sites in Alberta now, with BC next. Tell us how many extinguishers, eyewash stations and exit lights you have, and roughly how many people do the checks.

info@notifymeinspect.com
Email us about a pilot